THE BEST SIDE OF PERKIN ELMER AUTOSAMPLER

The best Side of perkin elmer autosampler

The best Side of perkin elmer autosampler

Blog Article

Mixing by aspiration—mixing of sample by aspiration as an alternative to shaking assures homogeneity on the sample and maintains mobile viability

The CytKick Max Autosample encompasses a Enhance manner that allows more rapidly sample processing, along with passive cooling for many plates/racks. A CytKick Max Accessory Package is integrated which contains four accent plates: two cooling plates and two tube adaptors, in addition to a Max dongle essential. A pc is just not integrated Along with the autosampler considering that 1 is provided with the cytometer.

To prevent probe crashes, which may have to have pricey probe substitution, the CytKick Max Autosampler instantly performs a probe self-calibration to help guarantee consistent positioning in the probe within each and every very well. The self-calibration verifies good function from the probe, lowers variability in probe positioning after some time to circumvent failures during plate runs, and assists boost reliability above the life of the program.

As opposed to other plate loaders that mix samples by shaking, which may not guarantee homogeneity with the sample, the CytKick Max Autosampler mixes samples by aspiration and stirring, enabling uniform mixing though preserving sample viability and causing dependable data with CVs less than ten% through the plate. The CytKick Max Autosampler also has a delicate combine method for fragile cell lines.

The autosampler’s indicator lights and warning techniques have already been created to make certain a person who's got walked far from the system can certainly see the method position always.

To keep up system adaptability, the guide sample probe is often available even when the loader is existing, and switching among tubes and plates is detected via software package and isn't going to need supplemental user intervention.

The CytKick Max Autosampler was built to decrease procedure down time. Automated sampling equipment are sometimes plagued by clogging or probe crashes. The Smart Probe, with a 200-micron diameter that is more substantial than most probes available while in the industry, minimizes cases of clogging.

The intuitive software program lets quick Finding out and data Examination. One example is, a warmth map see makes it possible for rapid screening and confirmation of samples although the instrument is buying details.

Simple transition—no disassembly, no added QC, no reboot demanded for conversion between plates and tubes

The CytKick Max Autosampler has two choices for processing samples in the significant-throughput environment: higher-throughput mode and Strengthen manner.

Self-calibration of the probe also enables the autosampler for being simply moved, so it could be shared amongst many devices.

The instrument style and design and software package ended up formulated with purchaser simplicity-of-use in mind. The CytKick Max Autosampler has fluidic bottles with sensors that inform the person in the event the fluids should get replaced.

Autocleaning of autosampler is completed pe autosampler through the instrument shutdown method consequently no additional person methods are essential to maintain system.

Starting an experiment Along with the Attune NxT cytometric application is simple. Employing a plate format view, buyers can generate compensation wells, determine instrument settings, and identify samples.

Report this page